Đại Lý HMI Proface - Đại lý HMI Weintek - Công ty Hiệp Lực
CÔNG TY TNHH KỸ THUẬT ĐIỆN
0903 733 157 0946 733 151
Màn hình Proface PFXGP4303TADCÔNG TY TNHH KỸ THUẬT ĐIỆN HIỆP LỰC MÀN HÌNH CẢM ỨNG PROFACE - WEINTEK LIÊN HỆ: 0946.733.151 (MR DUY) PFXGP4303TADGP4000 SeriesSố lượng: 1 Sản phẩm
Model PFXGP4303TAD Global Code PFXGP4303TAD Product Features 5" DC Analog Isolated Repair Status ✔ (Repair service is available, reparable.) MỌI NHU CẦU VỀ SẢN PHẨM HAY HỖ TRỢ KỸ THUẬT VUI LÒNG LIÊN HỆ TẠI ĐÂY Resolution 320 x 240 pixels (QVGA) Effective display area W115.2 x H86.4 mm [W4.54 x H3.40 in.] Display colors 65,536 Colors (No blink) / 16,384 Colors (Blink) Backlight White LED (Not user replaceable. When replacement is required, contact your local distributor.) Backlight service life 50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%) Brightness control 16 Levels (Adjusted with touch panel or software) Touch panel type Resistive Film (analog) Touch panel resolution 1,024 x 1,024 Touchpanel lifetime 1,000,000 times or more Language fonts Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean, Traditional Chinese and Simplified Chinese fonts are downloadable.) Character sizes Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts Font sizes Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1 8 x 8 dots 40 char. x 30 rows 8 x 16 dots 40 char. x 15 rows 16 x 16 dots 20 char. x 15 rows 32 x 32 dots 10 char. x 7 rows 1Other font sizes can be set up with the Editor software. Electrical specifications Rated input voltage 24 Vdc Input voltage limits 19.2 to 28.8 Vdc Allowable voltage drop 5 ms or less Power consumption 10.5 W or less In-rush current 30 A or less Voltage endurance 1,000 Vac, 20 mA for 1 minute (between charging and FG terminals) Insulation resistance 500 Vdc, 10 MΩ or more (between charging and FG terminals) Environmental specifications International safety standards Surrounding air temperature 0 to 55 °C [32 to 131 °F] Storage temperature -20 to +60 °C [-4 to 140 °F] Ambient humidity 10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation) Storage humidity 10 to 90 % RH (Wet bulb temperature : 39 °C [102.2 °F] max. - no condensation) Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels) Pollution degree For use in Pollution Degree 2 environment Corrosive gases Free of corrosive gases Air pressure (altitude range) 800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less) Vibration resistance IEC/EN 61131-2 compliant 5 to 9 Hz single amplitude 3.5 mm [0.14 in.] 9 to 150 Hz fixed acceleration : 9.8 m/s2 X, Y, Z directions for 10 cycles (approx. 100 min.) Concussion resistance IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times Noise immunity Noise Voltage : 1,000 Vp-p Pulse Duration : 1 µs Rise Time : 1 ns (via noise simulator) Electrostatic discharge immunity Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) Memory Application memory FLASH EPROM 16 MB (including a logic program area) Data backup SRAM 320 KB (Replaceable Lithium battery for backup memory) Logic program area FLASH EPROM 132 KB (Equivalent to 15,000 steps)*2 Variable area SRAM 64 KB (Replaceable Lithium battery for backup memory) Clock accuracy ±65 sec./month (deviation at room temperature and power is OFF)*3 2Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB. 3Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required. Interface specifications Serial (COM1) Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Parity: None, Odd or Even, Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115,200 bps, Connector: D-Sub9 (plug) Serial (COM2) Asynchronous Transmission: RS-485 (isolation), Data Length: 7 or 8 bits, Parity: none, Even or Odd, Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 to 115,200 bps, 187,500 bps (MPI), Connector: D-Sub9 (socket) USB (Type A) Conforms to USB 2.0 (Type A) x 1 Power supply voltage: 5 Vdc ±5 % Output Current: 500 mA or less Communication distance: 5 m [16.4 ft.] or less USB (mini-B) Conforms to USB 2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft] or less Ethernet IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1 SD card SD Card Slot x 1 Structural specifications Grounding Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) Cooling method Natural air circulation Structure IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*4 External dimensions W169.5 x H137 x D59.5 mm [W6.67 x H5.39 x D2.34 in.] Panel cut-out dimensions W156 x H123.5 mm [W6.14 x H4.86 in.] Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*5 Weight 0.8 kg [1.77 lb] or less 4The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP unit, be sure to confirm the type of conditions that will be present in the GP's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly. 5Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened. Dimensions External dimensions
Panel cut-out dimensions External dimensions with cable